Pulsation Damping

PNEUMATIC-AUTOMATIC-PULSATIONDÄMPING-SYSTEM
„ P.A.P.S. „
Aggressive pressure peaks in piping systems often exceed limits and the included components get damaged.
Particularly in fuel oil supply systems of large diesel engines serious danger can arise.
The pulsation damper type "PAPS" compensates these aggressive pressure peaks by a hermetically enclosed and controlled air volume. The installation takes place "IN LINE". The pressure impulses are led almost reflection-free on the air volume and will be absorbed so effectively. Constructional characteristics offer a high measure of security and ensure in each operating condition the control of the optimal damping-air-volume. Leakage-free, magnetic level-/air volume measuring and the pneumatic-automatic controlling arrangement for the preservation of the air volume guarantee the fully automatic operation.
 

DESIGN FEATURES / CHARACTERISTICS
- Optimum pulsation damping by enclosed air volume
- Auxiliary energy: Only compressed air 30 bar (starting air)
- Pneumatic control, without electrical energy
- Safety air volume limitation
- Magnetic, leaking-free level recording with indicator of status
- Damper will be adjusted to system requirements
- Automatically decompression if fuel pressure drops
- Suitable for heavy fuel systems by heating/insulation
- According to the classification regulations (UMS)

TECHNICAL DATA
Medium
Max. operating pressure
Max. operating temperature
Max. ambient temperature
Supply air pressure

Fuels, lub-/ hydraulic oils
16 bar
150 °C
45 °C
30 bar




For enlargement click
the illustration

Installation of the pulsation damper PAPS increases safety, leads to reduction of costs and simplifies design / construction.
In operation sensible components, measuring instruments and piping system will be permanently protected.

Pulsation damper in lubricating oil systems.
Actual the "PAPS" principle for pulsation damping will be installed in lubricating oil systems. Due to the block construction method the control unit is flexible applicable.
 

CONTROL UNIT for GAS VOLUME ADJUSTMENT
Typ: SE - P6 - 200

Control unit mounted on a Flange DN 200, PN 25

TECHNICAL DATA
Medium
Max. operation pressure
Max. operation temperature
Max. ambient temperature
Supply air pressure

Lubricating oil
16 bar (standart design)
100 °C
45 °C
30 bar




For enlargement click
the illustration

In co-operation with the German shipyard Flensburger Schiffabu-Gesellschaft mbH & Co. KG, the "PAPS" control unit will be installed in the lubricating oil system for main engine. Effective pulsation damping makes the system safe.