Controlling

Seagoing vessels have to operate with low sulphur fuels of 0,1% in ECA areas from January 2015. That means, that the diesel engines have to run with MGO fuels. The MGO must be cooled down to assure a viscosity not lower than 1,5 cSt.
 

MARINE TECHNIK delivers Cooler or Cooler Units automatic controlled or manual operated. Adapted to the diesel engine and the fuel system.

MGO COOLER UNIT
Type
MGO flow
Cooling water flow
Heat exchanged
Classification

designed for:
Main Engine
Power output

FCUA-110-CW
19,2 m³/h
19 m³/h
110 kW
DNV/GL


3x WÄRTSILÄ
ttl. 23.200 kW




For enlargement click
the illustration

Photo left: MGO Cooler Unit for AIDA Cruises.
Photo right: Schematic diagram with MGO Cooler Unit and Automatic HFO/MGO Change Over Valve. Designed and manufactured for 4 ships of the owner FINNLINES.

HFO/MGO CHANGE OVER CONTROL for 2 Generator Engines
  • Moderate, mild change over
  • no temperature shocks to the injection elements
  • free adjustable change over intervals
  • Fuel supply module remains in HFO operation
  • Easy expandable, simple retrofit
  •  
    TECHNICAL DATA
    Medium
    Max. operating pressure
    Max. operating temperature
    Voltage supply
    Connections

    HFO, Gas Oil
    16 bar
    150 °C
    24 V DC/AC or 230 VAC
    Flange DN25 (DIN 2501)




    For enlargement click
    the illustration

    Each HFO/MGO change over procedure is stressing the affected components. Fully automated systems help to save them.

    Automatic fuel change over valve skid with one common control box for three auxiliary-/ generator engines.
    Time delayed change over of the return-line valve ensures, that no HFO enter into the MDO tank.
    Each valve group be operated locally on the control box or from ECR. Automatic change over from HFO to MDO in case of voltage supply breakdown or working air pressure loss.
     

    HFO / MDO CHANGE OVER VALVE SKID
    for Main- and Generator Engines
    Typ: COV-3GE

    TECHNICAL DATA
    Medium
    Max. operating pressure
    Max. operating temperature
    Voltage supply
    Supply air pressure
    Connections

    HFO, Diesel fuels, Biofuels
    16 bar
    150 °C
    24 VDC
    working air 6...8 bar
    DN25 (DIN 2353)




    For enlargement click
    the illustration


    Automatic fuel change over with smoothly temperature adaption by homogeneous fuel mixing increases the lifetime and prevent the injectiuon elements of the diesel engine from demage by temperature shocks.
    Time delayed change over of the return-line valve ensures, that no HFO enter into the MDO tank.
    The change over can be released locally on the module or from ECR. Automatic change over from HFO to MDO in case of voltage supply breakdown or working air pressure loss.
     

    HFO / MDO CHANGE OVER MODULE
    for Main- and Generator Engines
    Typ: COV 25/30

    TECHNICAL DATA
    Medium
    Max. operating pressure
    Max. operating temperature
    Voltage supply
    Supply air pressure
    Connections
    Tank volume

    HFO, Diesel fuels
    16 bar
    150 °C
    24 VDC or 230 VAC
    working air 6...8 bar
    DN25 (DIN 2353)
    10 /30 / 50 ltr.




    For enlargement click
    the illustration

    Change over from HFO to MDO and vice versa is stress for the injection elements of the diesel engine.
    The integrated temperature compensating tank ensures a smoothly temperature adation to the engine.